A minimum order of $20 is required before checking out.

Murphy 0-1999F Dual Temperature Swichgage 100-350 VDC CD Ignition - Negative Ground FET Outputs- MDTM89-F-A-K

Availability:
Request Quote
MPN:
10703047
SKU:
77171940
Customer Reviews
SKU:
77171940
Weight:
0.91 LBS
so_moq:
1
so_qi:
1
NA:
NA
Special Order Available:
Increments of 1
QPO:
0
MPN:
10703047

The Murphy 0-1999F Dual Temperature Swichgage 100-350 VDC MDTM89-F-A-K is an electronic, dual-temperature monitor. It monitors two thermocouples, displays the temperature of the thermocouple selected, and has adjustable trip points for each input. A toggle switch provides for selection of the thermocouple to be displayed and/or the temperature trip point to be checked/adjusted. If either trip point is reached, the associated output “turns on” and can be used as a control signal, or to initiate alarms and/or shutdown. A “Push to Read” button, located below the selector switch, allows the operator to check the trip point and to see its value as adjustments are made. Two potentiometers, one on each side of the thermocouple selector switch, are provided for field-adjustment of the trip points.

Applications includes: Compressor suction/discharge temperature • Engine/compressor jacket water temperature • Engine exhaust temperature • Compressor cylinder temperature • After cooler temperature • Bearing temperature.

 

FEATURES:

  • FET (field effect transistor) Output
  • Monitor Inputs From Two Thermocouples
  • Adjustable Switch Trip Point For Each Input
  • Power From CD Ignition
  • Type K Ungrounded Thermocouple
  • Digital Reading in Fahrenheit

 

PRODUCT SPECIFICATIONS:

  • Part No.: MDTM89-F-A-K
  • Calibration: Fahrenheit
  • Case: Die cast aluminum
  • Thermocople type: Ungrounded K
  • Power Requirements (Operating Voltages): 100 to 350 VDC, CD ignition, negative ground (FET "field effect transistor" outputs) 0.5A @ 250 VDC maximum
  • Power Consumption: CD ignition: 350 μa @ 100V; 24 VDC: 0.5 watts
  • Output: output turns on above trip point; output turns off below trip point; two (2) isolated FET outputs, 0.5 amp @ 250 VDC
  • Ambient Cold Junction Compensation Range: 32 to 122°F (1°C from 0 to 50°C)
  • Operating Temperature: -4 to 158°F (-20 to 70°C)
  • Storage Temperature: -40 to 300°F (-40 to 150°C)
  • Reset Differential: FET models: Decreases 3 Degrees (°F)
  • Measurement Range: Monitor Range 0-1999°F
  • Accuracy: from 400-2000°F (204-1076°C) ±1.5% of reading. At calibration temperature
  • Laboratory Approvals: CSA and Factory Mutual* approved for Class I, Division 2, Group D, hazardous locations
  • Thermocouple Lead Length: 150 ohm lead resistance affects monitor accuracy less than 1°
  • Trip Point Accuracy: ±3°F (±2°C) of reading
  • Trip Point Adjustment Range: 0-1999 Degrees
  • Shipping Weight: 48 ozs (1.4 kg)
  • Shipping Dimensions: 10 x 9-1/2 x 6 in. (254 x 241 x 152 mm)


Product Condition: NEW
Murphy 100-350 VDC CD Ignition Dual Temperature Swichgage 0-1999F with Type K Thermocouple MDTM89-F-A-K

Note: Actual image not shown. Same style only.


Shop Products

“More than just a parts website. The account manager helped us plan ahead with inventory so we could avoid disruptions with our production schedule. Their engineering resources were available to assist with our application requirements. Highly recommend this team!”
— Satisified Customer

CAN'T FIND THE PART YOU NEED?

Shoot us an email or call (503) 802-1370

Contact Us