The Murphy Pressure Swichgage 25P-HL-300 is a diaphragm-actuated, pressure-indicating gage with built-in electrical switch. This switch exceed SAE standards and is used for tripping alarm and/or shutdown device. The gage mechanism is enclosed in a steel case coated to resist corrosion. A polycarbonate, break-resistant lens and a polished, stainless steel bezel help protect this rugged, built-to-last instrument. Accuracy and protection from moderate overpressure is assured by a unique, unitized diaphragm chamber. The gage pointer acts as a pressure indicator and as one switch pole which completes a circuit when it touches the adjustable limit contact. A built-in pulsation dampener helps eliminate pointer flutter and is removable for cleaning.

The Swichgage was specifically designed to protect engines/equipment in oil field, marine, irrigation, construction and trucking applications to monitor engine lube pressure, water pump pressure, hydraulic pressure, air pressure, etc.


PRODUCT SPECIFICATIONS:

  • Murphy Part No.: 25P-HL-300
  • Series: 25 Series
  • Base Model: 25P
  • Option: High and Low Contacts
  • Range: 0-300 PSI (2.1 kPa/MPa) [20 bar]
  • Diameter: 2-1/2 inch / 64 mm
  • Dial: White on black, dual scale
  • Case: Plated steel; mounting clamp included 
  • Bezel: Polished stainless steel, standard
  • Lens: Polycarbonate, high-impact
  • Ambient Temperature Range: -40° to 150° F (-40° to 66° C)
  • Process Temperature Range: -40° to 250° F (-40° to 121° C)
  • Process Connection: 1/8-27 NPTM brass
  • Sensing Element: Beryllium copper diaphragm
  • Gage Accuracy (% of Full Scale): ±3%, Lower 1/4; ±2%, Middle 1/2; ±3%, Upper 1/4
  • Adjustable Limit Contact: SPST contact; pilot-duty only, 2 A @ 30 VAC/DC; Normally Close (NC) when the low limit is met. Normally Open (NO) when pointer is in normal operating range. Contacts are gold flashed silver
  • Limit Contact Adjustment: By a 1/16 in. hex wrench through 100% of the scale
  • Limit Contact Wire Leads: 18 AWG (1.0 mm2) x 12 in. (305 mm)
  • Maximum Pressure: 1-2/3 x scale
  • Standard Settings: 75 psi (517 kPa) [5.0 bar]
  • High Settings: 225 psi (1.6 kPa/MPa) [15 bar]
  • Unit Weight: 11 oz. (0.31 kg)
  • Unit Dimension: 4-3/4 x 4-3/4 x 2-3/4 in. (121 x 121 x 70 mm)