- SKU:
- 77223339
- Weight:
- 0.34 LBS
- so_moq:
- 1
- so_qi:
- 1
- Estimated Special Order Ship Date:
- Special Order (ships approximately 2 Weeks)
- Special Order Available:
- Increments of 1
- QPO:
- 0
- MPN:
- 3410-2010
The Trumeter Model 3410 Electronic LCD AC/DC Hour Meter 3410-2010 provides a large display, with 0.28” [7mm] high characters. This model comes with an optional maximum of 3 “Redi-Alerts” to alert users when service is due.
PRODUCT FEATURES:
- Totally sealed from moisture and dirt
- AC or DC voltage input in the same unit
- Tachometer/Hour Meter versions
- Compact depth
- Fits in existing panel openings
- Always on display
- 15+ Year Battery Life
PRODUCT SPECIFICATIONS:
- Part No.: 3410-2010
- Display: LCD with large 0.28” [7mm] high figures black on light background
- Run indicator: Blinking decimal point
- Reset: Remote Reset
- Hour Meter Resolution: 0.01 or 0.1 Hour, displayed; 1 second, internal
- Accuracy: ± 0.1% @ room temperature, ± 0.2% over the specified temperature range
- Records & Displays: 9999999.9 - hours & 1/10’s or 999999.99 - hours & 1/100’s
- Inputs: 10-300VDC and 20-300VAC-50/60Hz <2mA, VIH 20VAC or 10VDC minimum, VIL 3VAC or 3VDC maximum
- Power: Self powered - battery life 15+ years
- Terminations: Standard 0.250” [6.4mm] spades 1 meter wire (inductive)
- Output: Format: Open-Drain MOSFET with Source connected to Common. Maximum Withstanding voltage: 30VDC, reference to Common Maximum Load current: 0.1Amp
- Sealing: Totally sealed
- EMC Compliance: EN61326:1997 with A1:1998 and A2:2001 for industrial environments
- Protection Against: Alternator load dump: 150V EMI (Electromag- netic Interface): +400V @ 500Hz inductive switching and reverse polarity
- Approvals: UL and cUL Recognized (file # ELIY2.E36690), CE, SAE, NEMA 4/4X compliant
- Weight: 1oz [28g]
- 1/4" Spade Terminal
- Flush Rectangular Case
- Dimensions: See image #2
ENVIRONMENTAL:
- Temperature: (Storage and Operating) -40 to +185 ̊F [-40 to +85 ̊C]
- Humidity: 95% RH per SAE J1378
- Vibration: 20g @ 10 to 80 Hz per SAE J1378
- Shock: 44 to 55g’s per SAE J1378
- Dielectric: 1000VAC 50/60 Hz for 1 minute
- Enclosure: Totally sealed from moisture and dirt, NEMA 4/4X, 12, & IP66 compliant from the front when properly mounted using the optional gasket.
- Compliance: Compliant to the European WEEE and RoHS Directives